- LTS-DPA
- DPA series current controller easy to operate, output high precision voltage, can provide high precision control to LED light. It can be controlled by button or RS232, realized 0-255 grade brightness adjustment. With trigger function, can control the light on/off by external signal, and it has power off saving function also. It is a stable performance, powerful light controller.
Features
1.Easy to operate, each channel can be controlled independently with high precision.
2.Digital display, button control, easy to understand.
3.Can communicate with PC by RS232.
4.With trigger, faster respond speed, high reliability.
5.Power off saving function.
Parameters
Item
LTS-DPA24##-#S
Remark
Communication mode
RS232
Luminance control mode
PWM adjust
Change PWM duty radio to adjust voltage
Efficiency
<92%
Storage function
set-up parameter of luminance will be kept while power off
External trigger input voltage
High level 5-24V
Number of channels
1、2 way
Luminance control
256 grade adjust
Power supply output voltage of fan
24V/2A
Drive mode
Constant-current, adjust the luminance by changing the duty radio
Input voltage
AC96-264V/47-63HZ
Control panel specification<LTS-DPA24200-1S>
Step 1: connected the light and controller (Reference to the picture on the right).
Step 2: if need the external trigger control, please connect the external trigger signal with the controller trigger interface.
Step 3: connect power (AC96-264V 47-63 Hz), press the red switch “-”, indicator light up, “o” uplifted, power on.
Step 4: If need to control the luminance by PC, please connect the PC with controller by RS232 data line in the power off status, then control by our demo program or the program you write yourself. Can set-up the each channel parameter manual when operated by serial port mode. That’s to say, the upper computer and controller all can set-up the parameter, no need mode swapping.
Mode setup
Mode
Output interface
Initial state is open mode
TS up, output state is open mode
Initial state is off mode
TS down, output state is off mode
Trigger port setup<LTS-DPA24200-1S>
This series controller is low level trigger controller. Total 1 group trigger ports, each has +/- mark. To input low level 5-24V to +/- port can achieve the trigger function.
Trigger introduction: when output initial state is open mode, input 5-24V to trigger port, light off; when output initial state is off mode, input 5-24V to trigger port, light on.
Wire connection method of the external trigger signal
Sequence chart
Normal on mode (MANU mode):
When connect external trigger signal, trigger “+” input high level 5-24V “-” ground connection, light off.
Normal closed mode (REMO mode):
When connect external trigger signal, trigger “+” input high level 5-24V “-” ground connection, light on.
Specification: T1 is trigger delay time, T1≦80us T3≦80us.
Controller model
Product
Model
Output current
Power
Number of channels
Remark
High power constant current controller
LTS-DPA24200-1S
5AX1
200W
1
Have communication, trigger function
LTS-DPA244001S
16AX1
400W
1
LTS-DPA24400-2S
8AX2
400W
2
Boundary dimension(mm)